Description: This circuit blanks the CRT starting just before retrace begins. Since the CRT sits at a -1200 volt potential, the blanking circuit must also be based at -1200 volts. Note the capacitors, C40, C41, and C43 which allow the gates that drive the intensity grid of the CRT to be isolated from the other electronics within the oscilloscope.
The described circuit functions as a blanking mechanism for a cathode-ray tube (CRT) display, specifically designed to activate just prior to the retrace period of the CRT's operation. This timing is critical as it prevents the display from showing unwanted artifacts during the retrace interval, thus ensuring a clear visual output.
The circuit operates at a high negative voltage of -1200 volts, which is the potential level at which the CRT operates. To accommodate this high voltage, the blanking circuit is designed to function within the same voltage domain. The isolation of the blanking circuit from the rest of the oscilloscope's electronics is achieved through the use of capacitors C40, C41, and C43. These capacitors serve a dual purpose: they provide the necessary coupling to allow the blanking signal to control the intensity grid while protecting the sensitive components of the oscilloscope from high voltage transients that may occur during operation.
In the schematic, the gates controlling the intensity grid are connected to the output of the blanking circuit, ensuring that the intensity of the CRT beam is modulated appropriately during the retrace period. The capacitors' values and types should be selected based on their voltage ratings and frequency response characteristics to ensure reliable performance at the operating voltage of -1200 volts.
Overall, the design of this blanking circuit is essential for maintaining the integrity of the displayed waveform on the CRT, allowing for accurate and clear visual representation of the electronic signals being measured. Proper implementation will enhance the functionality of the oscilloscope while ensuring user safety and equipment longevity.This circuit blanks the CRT starting just before retrace begins. Since the CRT sits at a -1200 volt potential, the blanking circuit must also be based at -1200 volts. Note the capacitors, C40, C41, and C43 which allow the gates that drive the intensity grid of the CRT to be isolated from the other electronics within the oscilloscope.
High voltage electrolytic capacitors in valve equipment can deteriorate if the equipment is unused for an extended period. This deterioration manifests as reduced capacitance and significantly increased leakage current. In some instances, the capacitor may become nearly short-circuited. Using equipment...
Instructions for constructing a simple Kirlian effect camera to capture high voltage corona discharges around objects, also referred to as aura photography.
The Kirlian effect is a phenomenon where high voltage electrical discharges create a visual representation of the energy field...
A 500 mV peak-to-peak triangular waveform centered around ground is applied to the amplifier, resulting in a peak current of 100 mA flowing through the inductor.
The circuit involves an amplifier configured to process a triangular waveform signal with a peak-to-peak...
Simple homemade oscilloscopes are not difficult to design and build. Various designs dating back to the 1930s have been studied, leading to the development of a simple oscilloscope that electronics hobbyists can construct using readily available parts today. The first...
High-voltage power supply circuit for fluorescent light power supply. Refer to that page for an explanation of the related circuit diagram.
The high-voltage power supply circuit designed for fluorescent lights typically consists of several key components that work together to convert...
Dynamic flip-flops ignore pulses at their inputs that are shorter than 40 ns or do not have TTL levels. This means that TTL flip-flops are not well-suited for capturing noise pulses with unknown durations and magnitudes. This issue is commonly...
In the miniature high-voltage DC generator, the circuit receives input from a 12 V DC power supply, which is amplified to produce a 10,000 V DC output. This process induces a pulsating signal of opposite polarity in the secondary winding...
An oscilloscope capable of displaying in X/Y mode and a reference "LO" signal source are required. In-phase and quadrature reference square wave signals are generated using a divide-by-4, 2-bit ring counter with two D-type flip-flops. To utilize an RF generator...
The general (and very basic) principle of operation is shown in Figure 1. The test signal is simply derived from the mains, and is a sinewave at 50 or 60Hz. In most locations, the sinewave will be distorted, but this...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.
By clicking Accept All, you agree to our use of cookies.
Learn more